東部深層海水創新研發中心

Low level 137Cs measurements in deep seawater samples

發佈日期:2016-09-10

標題
Low level 137Cs measurements in deep seawater samples
作者
M Aoyama, K Hirose, T Miyao, Y Igarashi
文件屬性
國外期刊
知識分類
基礎研究
出版年
2000
刊名
Applied Radiation and Isotopes
點閱數
2646

摘要

The ammonium phosphomolybdate (AMP) procedure for low level 137Cs measurements in deep seawater samples was examined, as a marked decrease in the recovery of AMP has been observed over several years. An improved AMP procedure is proposed: adjust the pH to 1.6–2.0, next add 0.26 g CsCl to form an insoluble compound, then add 4 g AMP to every 20–100 l seawater sample. Stir at a rate of 25 l air/min for 1 h, then recover the AMP/Cs compound after 6–24 h. The weight yield of AMP/Cs compound was about 98% of AMP for 20 l samples and the radiochemical 137Cs yield was 96–100%. The absolute efficiency of the HPGe coaxial well detector was 16% for 137Cs at 662 keV for 4 g AMP/Cs compound. Using the improved procedure, 137Cs activities in 20–100 l samples from sea surface to near bottom in the western North Pacific were measured. The 137Cs concentrations in deep water samples were lower than 0.1 Bq m−3 in 1997 and 1998. This procedure allows a wide range of applications of 137Cs as a transient tracer for oceanographic purposes, as high resolution water profiles are obtained due to the smaller volume of samples needed.