アンモニア/水を作動流体としてシェル&プレート式熱交換器を用いた海洋温度差発電の性能評価-熱源の温度および流量の影響
- 標題
- アンモニア/水を作動流体としてシェル&プレート式熱交換器を用いた海洋温度差発電の性能評価-熱源の温度および流量の影響
- 作者
- 安永 健, 池上 康之, 門出 政則
- 文件屬性
- 日本研究
- 知識分類
- 能源利用
- 出版年
- 2008
- 刊名
- 日本機械学会論文集 B編
- 卷
- 74
- 期
- 738
- 頁
- P 445-452
- 點閱數
- 3285
摘要
Performance test for ocean thermal energy conversion system was carried out using ammonia/ water mixture as working fluid. The system used a shell and plate type heat exchanger as evaporator and condenser. The effects of temperature difference between heat sources and mass flow rate on turbine power were confirmed. In the evaluation of the system, we adopted the ratio of net power since the pump powers for the heat resources play an essential role in collecting heat. The experimental results were compared with theoretical ones which were derived by maximal power output using ideal heat exchanger. The experimental result shows that the ratio of net power has the maximum value at an optimum condition due to a large amount of pump power consumption with an increase in mass flow rates. In the present test plant, the maximal net power reached about 1.2 kW and then the ratio of net power was around 5.6%.